Latest activity by Michael Strong-
Michael Strong created an article,
Design Software Recommended Desktop Spec
KB1270revc KB278 Consideration should be made for the fact that the design software is a 32bit multi-threaded Windows applica...
-
Michael Strong created an article,
Matrix Recommended Server Specification
KB1269revc KB277 Server Specs Recommended Additional Notes RAM 16GB RAM Max memory for SQL Express database engine is ...
-
Michael Strong created an article,
Can you provide a horizontal/lateral load capacity for any of your joist/roof connectors?
KB1235reva KB243We only publish lateral load values for our wall plate connectors or our LAB Angle Bracket range within our Technical Guide. However, we can also offer a lateral capacity (Directio...
-
Michael Strong created an article,
Can hangers be used upside down for increased uplift capacity?
KB1234reva KB242The UH, HUH and MHE hangers can be installed upside down (please enquire about other hanger types). To determine the product’s uplift values, the hangers are tested upside down. Th...
-
Michael Strong created an article,
Do you offer a hot dip galvanised coating or stainless steel version for any of your products?
KB1233reva KB241Each product within the Cullen range will specify the galvanised coating available on the technical data sheet. Z275 galvanised coatings are the minimum corrosion protection for Se...
-
Michael Strong created an article,
What resistance to corrosion is required for my metalwork?
KB1232reva KB240Our products are designed by our experts to provide the correct corrosion protection for your floor/wall/roof applications. A designated galvanised coating has been selected to mee...
-
Michael Strong created an article,
Can Cullen hangers be packed out if the incorrect width hanger has been supplied?
KB1231reva KB239When selecting a hanger it is always recommended to utilise the correct hanger width to ensure there is not too much movement within the hanger and the fixings can be adequately fi...
-
Michael Strong created an article,
Can Cullen hangers be fixed through Fermacell fireboard?
KB1230reva KB238In some instances you may need to fix Cullen hangers against fire resistant boards for fire separation. The only board that Cullen hangers can be fixed to is Fermacell boards (maxi...
-
Michael Strong created an article,
Can Cullen metalwork be fixed to RHS or SHS steel sections?
KB1229reva KB237 Cullen hangers have been tested in various applications and I-Section steel details can be found in the Cullen Technical Guide. Unfortunately Cullen hangers are not suitable for u...
-
Michael Strong created an article,
Can Cullen 90 degree hangers be used when the supported member is at an angle?
KB1228reva KB236Unless stated in our Technical Guide Cullen all 90 degree products must be installed at an angle range of no greater than +/- 2 degrees on plan. For any angle out with this toleran...